Cause Analysis of Gear Pump Motor Overheating
Gear pump is mainly used in oil, chemical, metallurgy, mining, power plants and other industries of oil media transfer, pressurization, fuel injection, and large oil and thin oil machinery and equipment circulation, in all types of machinery and equipment can do lubrication pump use.
Motor overheating gear pump is often in the course of the work of the problem, the specific analysis and testing are as follows:
1, the use of (flow, head) than the gear pump design requirements?
Select the appropriate type of motor spectrum 2, the proportion of more than gear pump Gear Motor configuration?
Configure the appropriate gear motor oil pump 3, packing gland pressure is too tight or mechanical seal spring is too tight?
Re-adjust the gland or mechanical seal spring compression 4, the pump assembly quality is poor, there is friction or motor and the pump shaft is not the same?
Check the assembly quality, eliminate assembly problems?
For the above conditions, one by one to do the analysis to find out the real cause of motor overheating, in accordance with the corresponding fault, maintenance treatment.

This article Keywords: gear pump    Oil pump

The above is the Gear pump motor overheating reasons we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> Gear pump motor overheating reasons
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send